Subject: 28 MW Steam Turbine Power Plant


Date: 11.12.2012 21:26:01

Details: Reviews 0

28 MW Steam Turbine Power Plant

Two (2) 14 MW Stal Laval Steam Turbines, one that operates at high pressure and other that operates at low pressure. Turbine 1: Norm: 107 barg, Max 127 barg, Steam Temperature before valve Norm 530 C, Max Temperature 540 C, Extraction pressure 45 barg, Back Pressure 25 barg. Turbine 2:  Norm: 25 barg, Max 40 barg, Steam Temperature before valve Norm 350 C, Max Temperature 425 C, Extraction pressure 6,2 barg, Back Pressure 1,8 barg Complete plant in good condition, well maintained and has provided reliable operation since installation., 50 HZ, 5250V, Complete plant.

 

To see the contact details please Login or Register
Contact Name:
Company Name:
Mobile Phone:
Phone:
Fax:
Country:
E-Mail:
Web:

Comments      Add New Message

Leave a reply

Replace the security code

We use cookies to improve your experience. By continuing to use our site, you accept our Cookies, Privacy Policy,Terms and Conditions. Close X