Failure to observe the below instructions can result in substantial damages to burners and thermocouples.
1) Max. load per charge of solid waste – class II:
MAXI 25 70L
MAXI 50 150L
MAXI 150 300L
2) Max. load per charge of oil-containing materials, ie filter cartridges. oily cotton waste, scrapings from centrifuges, etc.. MAXI 25 5L
MAXI 50 10L
MAXI 150 15L
3) Max. load per charge of high-calorific materials with explosion-like combustion, ie plastics, fishing net, etc.
MAXI 25 3 kg
MAXI 50 5 kg
MAXI 150 10 kg
4) Do not burn explosive materials such as closed containers or aerosols.
5) Remove ashes when needed and make sure that the air holes for the combustion air are always unblocked.
6) Do not feed the incinerator without min. 10 nim, vacuum in the combustion chamber, check U-tube (UM).
7) Too much draught can disturb a constant flame and prolong the heating-up time. Adjust damper in exhaust gas uptake and adjust after reaching working conditions.
8) Power loss during operation might cause overheating and consequently damage the incinerator