used very little (max 4000 hours) and are in excellent condition.
ORC turbine of 160 kW electrical and about 700 kW thermal,
Since 2001, Triogen has been developing and manufacturing systems for conversion
Organic Rankine Cycle (ORC) energy conversion systems. The generator
TRIOGEN ORC, which has been used in various application areas since
since 2005, is similar to a steam cycle, but uses a fluid
organic instead of water. Compared with steam, it allows
to achieve better performance and efficiencies by exploiting sources
of low-temperature heat. The Triogen ORC generator is
suitable for the conversion of heat from:
+ Natural gas engines
+ Biogas engines
+ Landfill gas engines
+ Biomass
+ Biodiesel engines
+ Diesel engines
+ Gas from flares
+ Gas turbines
+ Process heat
+ Furnace heat
+ Any heat source >350 °C
165 kWe DI
ELECTRICITY
WITHOUT FUEL
AND EMISSION-FREE
Power generation from waste heat
waste heat is sustainable because it generates
energy without the use of fuel
and without emissions, converting resources
that would otherwise be wasted.
+ Powers between 60 and 165 kWe.
+ Suitable for waste heat at temperatu-
high temperature (>350 °C)
+ Does not require an intermediate circuit
(oil- or water-fired)
+ Zero emissions, CO2 neutral
+ Unlimited range of application (sources of
heat)
+ Suitable for various cogeneration schemes
+ High degree of energy conversion.
ca, up to 20% of each workload
+ Low maintenance requirements
+ High reliability/availability
(> 97% measured)
+ High hours of operation
(> 8000 hours/year)
+ No need for an operator,
remote control
+ Suitable for access to incentives for
renewable energy
165
SYSTEM
TEMP. HEAT SOURCE INPUT > 350 °C
HEAT SOURCE 450 - 900 KWth
WATER COOLING 350 - 700 KWth
TEMP. COOLING 35 °C - > 55 °C (UP TO 90 °C, OPTIONAL)
CONTROL MANAGEMENT CONTROL
COMPUTERIZED
REMOTE MONITORING INTERNET TCP / IP
UNMANNED / REMOTE MANAGEMENT
PROCESS CHAMBER FOR OUTDOOR INSTALLATION,
IP 55/UVA PROTECTED;
STANDARD SIZE FOR WHEELED TRANSPORT
COMPONENTS
DIRECT EVAPORATION EVAPORATOR, WITHOUT CIRCUIT
INTERMEDIATE
GENERATOR HIGH-SPEED ASYNCHRONOUS MOTOR
SINGLE STAGE TURBINE 18000-28000 rpm
HYDRODYNAMICALLY LUBRICATED BEARINGS
TOLUENE LUBRICANT
PERFORMANCE
ELECTRIC POWER 60 - 165 kWe
ELECTRICAL CONNECTION 50 Hz, 400 V, three-phase
ZERO EMISSIONS.
MCC PROCESS CHAMBER DIMENSIONS
LENGTH 3.2 m 1.2 m
WIDTH 2.4 m 1.6 m
HEIGHT 4 m 2.2 m
WEIGHT 12,000 kg 2,000 kg
We use cookies to improve your experience. By continuing to use our site, you accept our Cookies, Privacy Policy,Terms and Conditions. Close X